Garage door installed on an Arizona home in Arizona
  • What the Standard Actually Says
  • Why You Might Not Need This
  • What Changes the Price
  • ROC #310144

Extension-to-Torsion Spring Conversion in Mesa, AZ

Before you pay for a conversion, find out whether a containment cable is all your extension springs need. We check your cables, headroom, and door weight, then quote the job that actually fits your door.

The service call is $85, covering a 22-point inspection and the first half hour of labor. A person answers after hours, and after-hours and weekend work carries a $250 call fee.

  • Women-Owned Family Business
  • ROC #310144
  • Licensed, Bonded & Insured
  • 90-Day Labor Warranty
  • Google Rated
Garage door installed on an Arizona home in Arizona

If somebody has told you your extension springs are unsafe and need converting to torsion, read "What the Standard Actually Requires," below, before you agree to anything.

An extension spring system with proper containment cables is a standard-conforming counterbalance system. That is what the American National Standard for residential garage door counterbalances requires and permits, and there is a good chance the fix you actually need is something much narrower than a conversion.

What the Standard Actually Requires

There is an American National Standard covering counterbalance systems on residential sectional garage doors: ANSI/DASMA 103. It is the document this whole question turns on, and almost nobody quotes it.

  1. What it requires is restraint, not torsion. Its wording is that a counterbalance spring or weight shall be restrained either on the inside or the outside.

  2. And restraint is a tested performance. The standard requires restraining devices to be type-tested, three units per type, cycled at maximum design spring load to one and a half times the spring's rated cycles. And the performance they have to meet is that they restrain the spring, its end loops, and its pulleys when the spring is destroyed.

  3. ANSI/DASMA 102, the specification for sectional doors, routes extension springs to that standard: counterbalance assemblies shall meet the requirements of ANSI/DASMA 103, and extension spring assembly design shall be in accordance with it.

  4. Read what that means. The standard does not say extension springs are substandard. It does not say they must be replaced. It says any counterbalance spring must be restrained, and it specifies a tested restraint that contains the spring, the end loops, and the pulleys at destruction.

  5. So an extension spring system with a compliant containment cable is not a system waiting to be fixed. It is the system the standard describes.

  6. And extension springs are current production, not a legacy defect. Clopay states that garage doors purchased through retail chains are generally supplied with standard extension springs on single-car doors ten feet wide or under, and EZ-Set torsion springs above that.

Garage door installed on an Arizona home in ArizonaGarage door service in Mesa, AZ
Garage door installed on an Arizona home in ArizonaTorsion spring conversion, Mesa & the Phoenix metro

So What Is the Actual Risk, and What Is the Actual Fix?

The risk is real, and it is specific: an extension spring without a containment cable.

  • DASMA publishes the position, and notice how measured the language is. If your garage door has extension springs, you need a safety cable that runs through the spring and secures to the wall or ceiling at each end. When the door is down, extension springs are under high tension. If the spring breaks, it may cause injury. A safety cable can contain a broken spring.

  • Now notice what DASMA does not say. It does not recommend converting to torsion. Anywhere. The remedy it names for an uncontained extension spring is a safety cable.

  • One more thing worth recording. The Consumer Product Safety Commission's garage door publication covers non-reversing openers, entrapment protection and door balance. It tells you to check that the springs operate properly, and it never mentions extension springs, safety cables or spring containment. If someone tells you a federal safety agency requires conversion, ask them to show you where. CPSC guidance does not mention it.

So the honest order of operations is:

1. Do you have containment cables? Look for a cable running through the middle of each spring, anchored at both ends.

2. If not, that is the fix, and it is a small job. DASMA's own instruction for an uncontained extension spring is to call a dealer for a safety inspection.

3. If you do have them and they are sound, your springs meet the standard's restraint requirement, and conversion becomes a question about geometry and hardware.

That is the simpler answer, and it is first on this page on purpose.

The Numbers Everyone Quotes, and Where They Come from

You will read that torsion springs last twice as long as extension springs. You will read specific figures: ten thousand cycles against twenty, or fifteen against thirty.

We went looking for the source, in the four documents where it would live.

  1. DASMA TDS #190, Factors Affecting Spring Cycle Life* organizes causes into handling, installation, and usage. It contains no cycle-life figures and no comparison between spring types. Its one relevant sentence is that spring cycle life may not necessarily coincide with door cycle life.

  2. ANSI/DASMA 109, the life-cycle testing standard, defines a cycle, references industry-average cycles per year, and contains no clause distinguishing torsion from extension in life-cycle testing.

  3. ANSI/DASMA 103 tests restraining devices at one and a half times the spring's rated cycles and specifies no absolute minimum and no comparison by spring type.

  4. ANSI/DASMA 102 defines a cycle but publishes no usage table or comparison.

  5. No published cycle-life comparison between extension and torsion counterbalance systems exists in any of them. The figures circulating online are not attributed to a manufacturer, a standard or a standards body, and the ones we found on competitor pages contradict each other: ten thousand on one, fifteen to twenty on another, thirty on a third.

  6. The same goes for "torsion causes less opener wear." We could not source it either.

  7. What is published is one balance figure, and it is blind to spring type. ANSI/DASMA 109 sets up every test door counterbalanced so that no more than the larger of 5% of the door weight or ten pounds of applied force is needed to open it by hand from closed. Extension and torsion go into the test against the same line.

  8. We are not telling you torsion is no better. We are telling you that the numbers used to sell it are not sourceable, and that a company quoting them cannot show you where they came from either.

The Real Reasons People Convert

There are three; they are all geometric or mechanical, and none of them is a scare.

You want a jackshaft opener.

A wall-mounted jackshaft opener drives the torsion shaft directly. It cannot work unless a torsion shaft is present. So if you want the ceiling clear, or you have a high ceiling, or you want the storage above the door, the conversion is not the goal; it is the prerequisite. DASMA adds that jackshaft operators on standard-lift tracks require specific provisions from the door maker to keep the cables tight, so a converted door is not automatically jackshaft-ready.

The header can carry it, and you would rather it did.

A torsion system anchors its load into the header above the opening. An extension system carries load back along the horizontal tracks and their supports. Which arrangement suits a given garage is a structural question about that garage, and it is a legitimate reason to prefer one.

Headroom, and Why There Is No Universal Number

You will be given a number. It will be wrong, or at least somebody's hardware presented as physics.

Here is Amarr's published table, and look at what it shows. On 12-inch-radius track, extension springs need 12 inches of headroom, and 15 inches with an opener. On a 12-inch-radius track, torsion springs need 12 inches of headroom and 15 inches with an opener. On 15-inch-radius track, both need 15 inches, and 18 with an opener.

  • So there is no universal number, and headroom can cut against conversion. Clopay publishes a 10-inch minimum for extension against 12 for torsion, and Garaga publishes 8½ against 12, so converting can raise the requirement. What else changes the number is the track radius, which is a hardware choice.

  • Where headroom genuinely constrains you is at the bottom of the range, and manufacturers publish specific configurations for it: low-headroom front mount, low-headroom rear mount, double-track low-headroom, and, on extension springs, a quick-turn bracket that reaches 8 inches on 12-inch-radius track. Published low-headroom figures across manufacturers range from around 12 inches at the top down to about 4.5 inches for a rear-mounted low-headroom torsion system, and low-headroom extension systems fall at the same end of the range.

  • Any single headroom number you are given describes someone's hardware, not your garage. We measure yours.

That is the honest answer: headroom is hardware-specific, and it has to be measured on your door, with the track you have or the track you would be getting.

When Conversion Is Not the Answer

  • Your door is wind-load rated. Clopay's own torsion conversion kit carries the restriction: not available for use on stock wind-load doors. A rated door is a tested assembly, and DASMA's guidance on part substitution states that non-identical components may weaken the overall assembly and that a certifying agency may invalidate the certification. If your door has a wind-load label, this conversation changes.

  • The header or the spring anchor pad is not up to it. Manufacturers publish minimum spring anchor pad requirements, and DASMA's inspection guidance calls for structurally sound, load-bearing members. On an older garage, that is something to look at.

  • Your door's weight is outside the available kit. Conversion kits are cataloged by door size and door weight band, in ranges such as 109 to 133 pounds and 219 to 243 pounds. A door outside a published band has no listed kit.

  • The headroom genuinely is not there, below the low-headroom thresholds, at which point the published remedy is structural work on the opening. That is a different trade and a different budget.

  • It is a one-piece tilt-up door. The sectional standards are limited to sectional doors, so a one-piece door falls outside them. We service one-piece doors. We are not going to tell you they can or cannot be converted from a web page.

It Is a Manufacturer-Supported Operation, and It Is Sold by Weight

Two facts that between them explain why we cannot quote this over the phone.

Conversion is legitimate, not a workaround. Clopay manufactures and sells torsion conversion kits as an OEM part, cataloged by door size.

And the kit is selected by the actual weight of your specific door. Clopay's catalog lists them in weight bands: the kit for a 16-by-7 door at 156 to 170 pounds is a different part from the kit for a 16-by-7 door at 219 to 243 pounds.

This means the price of your conversion depends on your door's weight, and nobody knows that until someone weighs it or calculates it from the door's construction. A number given on the phone is a guess, and a guess on this job is a guess about the part that holds a two-hundred-pound door over your car.

What we will do is measure, establish the weight, check the headroom against the track radius, look at the header, confirm whether the door is rated, and then quote. If the answer is that containment cables are what you actually need, that is what the estimate will say.

What You Are Actually Buying

Worth setting out, because "conversion" sounds like swapping springs and it is not. We are not publishing a procedure, and this work is not a homeowner job, but you should know what is on the invoice.

Garage door installed on an Arizona home in Arizona
  1. A torsion shaft running the width of the opening above the door, which does not exist on your door today.

  2. Bearing plates and a center bearing to carry it, mounted to the header and the jambs.

  3. A spring anchor bracket at the center of a conventional system, which is where the load ends up and why the header matters. Some OEM kits wind from the end plates instead and need no center pad.

  4. Torsion springs, sized to the door's weight and to the cycle rating you choose. The weight is measured or calculated, not estimated.

  5. Cable drums, matched to the door height and the track radius, and new lift cables, because the extension system's cables run differently and are not reused.

  6. And the extension system comes out. Springs, pulleys, the cables and the containment cables, plus whatever they were anchored to.

  7. Then the door gets balanced to the new system, which is the step that decides whether the job was worth doing. A converted door that will not hold at three or four feet off the floor has been converted badly, and it is the first thing to check afterward.

If You Have a Wayne Dalton TorqueMaster

This comes up constantly, so here is what is actually published.

Wayne Dalton supports TorqueMaster. It publishes replacement springs and installation manuals for both TorqueMaster and TorqueMaster Plus.

What we could not find is any Wayne Dalton publication addressing conversion of a TorqueMaster door to a conventional torsion system. No recommendation, no prohibition, no bulletin. Nothing either way.

So a company proposing that conversion is working outside published manufacturer guidance and should be able to explain why for your specific door. Sometimes there is a good reason, particularly on the original TorqueMaster, where the gearbox internals are no longer made. Our Wayne Dalton page goes through that in detail.

One number to be careful of. Be careful with cycle-life figures for TorqueMaster versus standard torsion springs. No published comparison exists.

What Affects the Price

  1. Your door's actual weight, which selects the kit and the springs.

  2. The track radius you have and whether it is changing.

  3. Headroom and whether a standard, low-headroom, or double-track configuration is needed.

  4. The header and spring anchor pad and whether they need work first.

  5. Whether the door is wind-load rated, which may end the conversation.

  6. Whether an opener is involved, particularly if a jackshaft is the actual goal.

  7. Whether containment cables would do instead, which is a much smaller job.

Garage door installed on an Arizona home in ArizonaGarage door service in Mesa, AZ

How the Visit Goes

  1. 1.

    Tell us why you are asking.

    Somebody recommended it, you want a jackshaft opener, or a spring has broken. The three lead to different conversations.

  2. 2.

    You call, and we schedule it.

    This is a measuring visit rather than an emergency.

  3. 3.

    A text reminder before the appointment, and an ETA text on the day.

  4. 4.

    The technician checks whether you have containment cables first, because that decides whether safety is even part of the discussion.

  5. 5.

    He measures headroom, sideroom, and backroom, and records the existing track radius.

  1. 6.

    He establishes the door's weight and checks the header and anchor pads.

  2. 7.

    He checks for a wind-load label.

  3. 8.

    You get an estimate, and if containment cables are the right answer, that is what it says.

  4. 9.

    You decide.

    Nothing is ordered until you've approved it.

  5. 10.

    On completion, the door is balanced by hand with the opener disconnected, and the safety reverse is tested.

Why Bring Us Out

We check for containment cables before discussing anything else, because the standard's requirement is restraint, and the smaller fix comes first.

We do not quote cycle-life numbers, because no published comparison between extension and torsion exists in ANSI/DASMA 102, 103, 109 or TDS 190, and we checked all four.

We measure headroom against your track radius rather than applying a number off a web page, including our own.

We tell you when a wind-load label changes the answer.

We weigh the door, because the kit and the springs are selected from that and nothing else.

Any brand, any age, including extension springs, TorqueMaster, and one-piece doors. No minimum job or invoice.

If we get it wrong, we make it right. Ninety days on our labor, and manufacturer parts warranties honored.

What Mesa Customers Say

Frequently Asked Questions

Are extension springs unsafe?

Uncontained ones pose a real risk, and DASMA's published remedy is a safety cable threaded through the spring, anchored at both ends. Contained ones meet the restraint requirement of ANSI/DASMA 103, the American National Standard for residential counterbalance systems, which asks for restraint on any counterbalance spring and specifies a tested restraint that holds the spring, its end loops, and its pulleys when the spring is destroyed.

Do I need to convert to torsion?

Not for safety, if your springs are properly contained. There are three real reasons people convert: headroom and track geometry, the need for a jackshaft opener that requires a torsion shaft, and a structural preference for putting the load into the header. If none of those apply to you, the honest answer may be no.

Someone told me torsion springs last twice as long.

Ask them for the source. We looked in DASMA TDS 190, ANSI/DASMA 109, ANSI/DASMA 103, and ANSI/DASMA 102, and there is no published cycle-life comparison between extension and torsion systems in any of them. The figures circulating online contradict each other, and none is attributed.

How much headroom does a torsion conversion need?

There is no universal number, and be wary of anyone who gives you one. Amarr publishes extension and torsion as needing the same headroom at the same track radius: 12 inches on 12-inch-radius track, 15 with an opener. What actually changes the requirement is the track radius. Low-headroom configurations exist down to around four and a half inches with the right hardware.

Can any door be converted?

No. Wind-load-rated doors are excluded by at least one manufacturer's own conversion kit; the header and spring anchor pads have to be sound; the door's weight has to fall within an available kit band; and below low-headroom thresholds, the remedy becomes structural work on the opening.

Why can't you give me a price on the phone?

Because conversion kits are cataloged by door size and door weight band, the correct part depends on your specific door's weight. A price given over the phone would be a guess about the component holding a two-hundred-pound door over your car.

I have a Wayne Dalton TorqueMaster. Should I convert it?

Possibly, particularly on the original TorqueMaster, where the gearbox internals are no longer manufactured. What we will not do is tell you Wayne Dalton requires it, because Wayne Dalton publishes nothing on converting TorqueMaster to conventional torsion, in either direction. Our Wayne Dalton page covers the options.

My extension spring just broke. Is conversion my only option?

No. Replacing extension springs is an ordinary repair, and our spring repair page covers it. Conversion is a separate decision, and a broken spring is a reason to have the conversation.

Do you fit safety cables on their own?

Yes, and on an uncontained extension spring system it is usually the right first job. DASMA's published instruction for a door with extension springs and no safety cable is to call a dealer for a safety inspection.

Where We Work

Spring conversion, extension spring repair and containment cables across the Phoenix metro:

See the full service area

Look for a cable running through the middle of your springs.

If there is one, anchored at both ends, your counterbalance meets the standard, and this becomes a question about headroom and hardware. If there is not, that is the job to price first, and it is a much smaller one.

Request an Estimate

Step 1 of 2